Products

Medical Pump

 

Sales points

1. Auto-recognize the syringe size: 10, 20, 30, 50ml.


2. KVO (Keep Vein Open) function. After finish setting infusion amount, for prevent to form thrombus, keep to infusion at the lowest rate 0.1ml/h.  

 

3. Bolus (Quick Infuse) function.  

 

4. Purge (Evacuate Bubble) function.

 

5. RS232 port, able to connect with the computer.

 

6. The bright & large LCD screen, easy look .


7. Wide flow rate range from 0.1-1600ml/h .

 

8. The battery can be used continuously for 6 hours after full charged

 

 

Features

 

Dimensions (mm)

271(L)×167(W)×287(H)

Weight

3.6kg

Power supply

AC 100V~AC 242V,50/60HZ(±1 HZ)

Built-in battery

DC 12V 2800mAh

Battery Model

JBT Ni-MH, rechargeable

Battery Continuous 

Use Time

At least 6hrs for single channel(Fully charged new battery, under 5ml/h running)

 

Power consumption

≤42 VA

Infusion Flow Selection

0.1ml/h~1600ml/h, original value is 0.1ml/h

Bolus rate

Syringe 50ml:1600ml/h

Syringe 30ml:900 ml/h

Syringe 20ml:600 ml/h

Syringe 10ml:400 ml/h

 

Infusion Range

0.1ml~9999.9ml, original value is 0.1ml

Flow Rate Precision

±3%

Occlusion Pressure

High:110kPa±20kPa (825mmHg±150 mmHg)

Middle:80kPa±30kPa  (600mmHg±225mmHg) 

Low:60kPa±20kPa  (450mmHg±150 mmHg)

 

The biggest output 

pressure

975mmHg(130kPa)

Use Environment

Temperature:  5~43

Relative Humidity:90%RH (Under without condensation status)

Atmospheric Pressure:860hPa~1060hPa

 

Storage Environment

Temperature:-40~+55

Relative Humidity:90%RH (Under without condensation status)

Atmospheric Pressure:860hPa~1060hPa

Waterproof Level

IPX4

Electric Shock Protection

Class I, Type CF

Alarm

occlusion, nearly finish, finish, standby (no operation) low 

battery, battery exhausted etc.

 

Function

transfusion amount display, flow rate display, infused 

volume display

 

 

 

Special Function

 

KVO (Keep Vein Open)

After finish setting infusion amount, for prevent to form 

thrombus, keep to infusion at the lowest rate 0.1ml/h. 

 

Power Supply Switching 

Function

When AC power is disconnected, automatically switch into 

battery power supply and give indication. When the AC power 

is connected, automatically switch into AC power working.

 

Repeat Alarm Function

If the alarm real reason is not be resolved within 2 minutes 

after press “SILENCE” button, it will give alarm again to remind

to resolve the 

problem.

 

 

 

Data Memory Function

Able to save the latest setting alarm volume level, brand, 

occlusion pressure level for use next time. Able to save for 

five years.

 

Battery Protection Alarm

For protect battery and safety infusion, the battery power 

will be displayed as different levels in sound and light from 

nearly finish to exhausted.

 

Move alarm

When try to move or take the syringe away, it will give alarm.

 

Sun-520 Syringe Pump's Advantages  

1. Our syringe pump could use all brands through calibration (default setting is Terumo).
2. Auto-recognize the syringe size: 10, 20, 30, 50ml.
3. Wide flow rate range from 0.1-1600ml/h.
4. Two LCD screens can be worked separately or meanwhile.
5. Available for adjust alarm volume (3 levels), occlusion pressure (3 levels).

6. Power Switching Function:When AC power is disconnected, automatically switch

into battery power supply and give indication. When the AC power is connected,

automatically switch into AC power working.

7. Repeat Alarm Function: If the alarm real reason is not be resolved within 1 minutes

after press “SILENCE” button, it will give alarm again to remind to resolve the problem.

8. Battery Protection Alarm: For protect battery and safety infusion, the battery power

will be displayed as different levels in sound and light from nearly finish to exhausted.

9. Double confirmation function when flow rate≥300ml/h, make safer and avoid

misoperation.

10. The data can be cleared, make safer.
11. Lock the control panel during infusion, make safer.
12 For avoid misoperation, press “POWER” for 3 seconds to close the pump.
13. Real display the battery power in panel.
14. Different alarm light display in red and yellow color base different priority level.
15. RS232 port, able to connect with the computer.

16. KVO (Keep Vein Open) function. After finish setting infusion amount, for prevent to form

thrombus, keep to infusion at the lowest rate 0.1ml/h.

17. Bolus (Quick Infuse) function.
18. Purge (Evacuate Bubble) function.
19. The bright & large LCD screen, easy look
20 The battery can be used continuously for 6 hours after full charged.

21. The chip in syringe pump is be processed by ourselves on SMT machine production line instead

of by manual work, as weld every point by hand.

22. CPU control, stable function, high reliability.

Back Up