SUN-900 Plus Infusion Pump
Display |
4.3" LED color screen with 272×480 display |
Three operating modes |
Rate Mode, Time Mode and Volume Mode |
New features |
NIBP and SpO2 |
Drug library |
with 210 kinds of medicine |
Heating function |
Suitable for infusing in winter or there is requirement for the fluid medication temperature. |
Remote Controller |
Remote Controller makes operating more convenient. |
Central monitoring system |
Central monitoring system is optional, the infusing status of each pump is displayed in real time at the central station through wireless transmission. |
Operation |
Simple and convenient in operating, intuitive presence of working status. |
Alarm |
Audible and Visible alarms |
|
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
Storage |
1500 history events |
Language |
Support multi language display |
Size |
Size: 188 mm(L)*198 mm(W)*228 mm(H) |
Weight |
Net Weight: 2.2kg |
Technical Specifications
Adjustable Drop Rate Range |
1~400 drops/min (step: 1 drop/min) |
Adjustable Flow Rate Range |
1~1200 ml/h (step: 0.1 ml/h) |
Purge Rate |
800 ml/h |
KVO Rate |
1~3 ml/h |
Infusion Volume Range |
1 ml~9999.9 ml (step: 0.1 ml) |
Maximum Accumulated Volume |
9999.9 ml (step: 0.1 ml)
|
Time Range |
1 min~9999 min (step: 1 min) |
Transfusion accuracy |
Within 3% (to choose the high quality and had calibration apparatus infusionis) |
Occlusion Alarm |
Lower: 300mmHg ± 100mmHg Medium: 500mmHg ± 100mmHg High: 800mmHg ± 200mmHg |
Alarm |
Occlusion,Air, Door open,Infusion Complete, Signal error,Battery undervoltage, Net, power off, Empty bottle, Low voltage, Error setting |
Air Bubble Detector Method |
ultrasonic wave, sensitivity: ≥ 25 μL |
Fuse |
F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity), 2 pcs (installed inside pump). |
Power Supply |
AC 85~265V, 50/60Hz; |
Internal Battery |
11.1V rechargeable li-ion battery. Capacity: ≥ the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for 8 hours (Medium rate specified by GB 9706.27-2005). |
Power |
≤ 40VA |
Size |
188 mm(L)*198 mm(W)*228 mm(H) |
Weight |
2.2KG |
Environment Requirements |
Transport Ambient Temperature: -30℃~+55℃ Relative Humidity: 20%~95% (non-condensing) Atmosphere Pressure: 70kPa~106kPa Storage Ambient Temperature: -30℃~+55℃ Relative Humidity: 20%~95% Atmosphere Pressure: 70kPa~106kPa Operation Ambient Temperature: +5~+40℃ Relative Humidity: 20%~90% Atmosphere Pressure: 86kPa~106kPas |
Calibration function |
disposable IV set of any brand is suitable for this pump |
Three working modes |
Rate/Volume/Time mode |
Alarm |
Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
Infusion monitoring system (Optional), the status of each pump is displayed in real time at the central station through wireless transmission. |
|
4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions. |
|
Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication |
Blood Pressure and SPO2 Part
NIBP Range
Average deviation is not more than 5mmHg
Standard deviation is less than or equal to 8mmHg
Adult SYS 40mmHg~280mmHg
MEAN 20mmHg~240mmHg
DIA 10mmHg~220mmHg
Pediatric SYS 40mmHg~220mmHg
MEAN 20mmHg~170mmHg
DIA 10mmHg~160mmHg
Neonate SYS 40mmHg~135mmHg
MEAN 20mmHg~110mmHg
DIA 10mmHg~100mmHg
Static pressure Range 0mmHg~300mmHg
Error 3mmHg
Resolution: 1mmHg
NIBP measurement model
Manual
Cycle(automatic):according to the set time interval automatically start the NIBP measurement, the time interval of optional: 1min, 2min, 3min, 4min, 5min, 10min, 15min, 30min, 60min, 90min
Fast:continuous NIBP measurement, interval is 5min
NIBP alarm
High pressure alarm: >90mmHg-160mmHg
Low pressure alarm: <50mmHg-90mmHg
Accuracy:±5%
Overvoltage protection
Adult 280 mmHg±10 mmHg
Children 237 mmHg±3 mmHg
Newborn 147 mmHg±3 mmHg
SPO2
Range 0%~100%
Resolution 1%
Accuracy 70% to 100%, precision is 2%
0% to 69%, its precision is not defined
SPO2 alarm
Upper limit 100%
Lower limit 90%
Alarm numerical accuracy 3%
Alarm time accuracy 2s
Pulse rate
Range 20bpm~300bpm
Resolution 1bpm
Accuracy 3bpm
Pulse rate alarm
Upper limit 120bpm
Lower limit 50bpm (Alarm value is the default infusion pump)
Alarm numerical accuracy 5%
Alarm time accuracy 2s
NIBP Cuff requirement
Human body contact parts materials Waterproof cloth
Size 515mm(L)×145mm(W), ±5%
Finger clip type blood oxygen sensor
Type:Finger clip type
Wire length:3000mm, ±5%
Probe body contact parts materials:Silica gel