Medical Pump

 

Specifications


Large LCD display, with backlight, suitable for working in various ambient light conditions.

Disposable IV set of any brand is suitable for this pump

Three working modes: Rate/Volume/Time mode

Purge, KVO function

Heating function is optional, suitable for infusing in winter or there is requirement for the medication temperature.

Remote Controller makes operating more convenient.

Central monitoring system is optional, the infusing status of each pump is displayed in real time at the central station through wireless transmission.

Simple and convenient in operating, intuitive presence of working status.

Audible and Visible alarms

Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

Size: 188 mm(L)*198 mm(W)*228 mm(H)

Net Weight: 2.2kg

 

Technical Specifications

Pump Type

Drip type infusion pump

Pumping Way

Peristalic fingers

Adjustable Drop Rate Range

1~400 drops/min (step: 1 drop/min)

Adjustable Volume Rate Range

1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h)

Flow Precision

Within 3% more or less(using the IV set appointed by the manufacturer or calibrated high quality IV set)

Mechanical precision

within 2% more or less

Purge Rate

800 ml/h

KVO Rate

1 ml/h (1~300 ml/h)

3 ml/h (greater than 300 ml/h)

Infusion Volume Range

1 ml~9999.9 ml (step: 0.1 ml)

Maximum Accumulated Volume

9999.9 ml (step: 0.1 ml)

 

Time Range

1 min~9999 min (step: 1 min)

Occlusion Alarm Threshold

High: 800 mmHg+-200 mmHg (106.7kPa+-26.7kPa)

Medium: 500 mmHg+-100 mmHg (66.7kPa+-13.3kPa)

Low: 300 mmHg+-100 mmHg (40.7kPa+-13.3kPa)

Alarm

Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

Air Bubble Detector Method

ultrasonic wave, sensitivity: more than or equal

25 μL

Fuse

F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity), 2 pcs (installed inside pump).

Power Supply

AC 85~265V, 50/60Hz;

Internal Battery

11.1V rechargeable li-ion battery. Capacity:more than or equal 2000mAh;

the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for 8 hours (Medium rate specified by GB 9706.27-2005).

Power

less than or equal 40VA

Size

188 mm(L)*198 mm(W)*228 mm(H)

Weight

2.2KG

Environment Requirements

Transport

Ambient Temperature: -30°C~+55°C

Relative Humidity: 20%~95% (non-condensing)

Atmosphere Pressure: 70kPa~106kPa

Storage

Ambient Temperature: -30°C~+55°C

Relative Humidity: 20%~95%

Atmosphere Pressure: 70kPa~106kPa

Operation

Ambient Temperature: +5~+40°C

Relative Humidity: 20%~90%

Atmosphere Pressure: 86kPa~106kPas

Calibration function

disposable IV set of any brand is suitable for this pump

Three working modes

Rate/Volume/Time mode

Alarm

Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

infusion monitoring system (Optional),

the status of each pump is displayed in real time at the central station through wireless transmission.

4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions.

Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication

 

 

.jpg

Back Up