Sales points
1. could use all brands through calibration (default setting is Terumo), syringes including 10ml, 20ml, 30ml, 50ml. .
2. KVO (Keep Vein Open) function. After finish setting infusion amount, for prevent to form thrombus, keep to infusion at the lowest rate 0.1ml/h.
3. Bolus (Quick Infuse) function.
4. Purge (Evacuate Bubble) function.
5. The bright & large LED screen could be clear seen far from 10 meters.
6. The battery can be used continuously for 5 hours after full charged.
7. Power Switching Function.
Features
Dimensions (mm) |
320(L)×145(W)×120(H) |
Weight |
about 3Kg |
Power supply |
AC90-242V 47-63HZ |
Built-in battery |
DC 12V 1300mAh |
Battery Model |
JP-HSE-1.3-12V |
Battery Continuous Use Time |
Above 6hrs |
Power consumption |
≤18VA |
Infusion Flow Selection |
0.1ml/h~599.9ml/h, original value is 0.1ml/h |
Infusion Range |
0.1ml~999.9ml, original value is 0.1ml |
Flow Rate Precision |
±3%(50ml/h≤ Flow Rate ≤599.9ml/h) |
Occlusion Pressure |
262.5~712.5mmHg±150(35~95kpa±20) |
Use Environment |
Temperature 5℃~43℃ Relative Humidity ≤90%RH (Under without condensation status) Atmospheric Pressure 860hPa~1060hPa |
Use Environment |
Temperature 5℃~43℃ Relative Humidity ≤90%RH (Under without condensation status) Atmospheric Pressure 860hPa~1060hPa |
Storage Environment |
Temperature -40℃~+55℃ Relative Humidity ≤95%RH (Under without condensation status) Atmospheric Pressure 860hPa~1060hPa |
Waterproof Level |
IPX1 (drip-proof) |
Electric Shock Protection |
Class I, Type BF |
Flow Rate Precision |
±3% |
Alarm |
self-test, occlusion, nearly finish, finish, low battery, battery exhausted, standby (no operation), move (including syringe drop, wrong fastening of syringe, shift of syringe)
|
Basic Function |
Automatically detect syringe type, indicate total infusion volume, indicate flow rate, indicate power supply, standby automatic alarm and KVO functions.
|
Special Function
KVO (Keep Vein Open) |
After finishing predetermined infusion volume, to prevent the formation of thrombus, continue infusion with preset minimum rate (0.1 ml/h).
|
Power Supply Switching Function |
When the AC power supply is off, it will automatically switch to built-in battery power supply and prompt at the same time. When AC is switched on, it is automatically converted back to AC supply.
|
Repeat Alarm Function |
After the operator presses the “SILENCE” key, if the reason causing the alarm has be untreated for 2 minutes, the alarm will sound again to alert the operator to solve the problem.
|
Battery Protection Alarm |
In order to protect the battery and ensure infusion safety, there are different levels of acousto-optic prompts when the electric quantity of the battery is changing from close to depletion to almost depleted.
|
Sun-502 Syringe Pump's Advantages
1. Our syringe pump could use all brands through calibration |
2. Auto-recognize the syringe size: 10, 20, 30, 50ml. |
3. Available for adjust alarm volume (3 levels), standby alarm delay time (1-9min), nearly finish alarm interval (0-3min). |
4. Power Switching Function:When AC power is disconnected, automatically switch into battery power supply and give indication. When the AC power is connected, automatically switch into AC power working. |
5. Repeat Alarm Function: If the alarm real reason is not be resolved within 2 minutes after press “SILENCE” button, it will give alarm again to remind to resolve the problem. |
6. Battery Protection Alarm: For protect battery and safety infusion, the battery power will be displayed as different levels in sound and light from nearly finish to exhausted. |
7. Double confirmation function when flow rate≥300ml/h, make safer and avoid misoperation. |
8 The data can be cleared, make safer. |
9. Lock the control panel during infusion, make safer. |
10 For avoid misoperation, press “POWER” for 3 seconds to close the pump. |
11. Able to set flow rate by single digit, tens digit and hundreds digit separately, not need to increase from single digit. |
12. KVO (Keep Vein Open) function. After finish setting infusion amount, for prevent to form thrombus, keep to infusion at the lowest rate 0.1ml/h. |
13. Bolus (Quick Infuse) function. |
14. Purge (Evacuate Bubble) function. |
15. Press "mL", real-time display infused volume. |
16. The bright & large LED screen could be clear seen far from 10 meters. |
17. The battery can be used continuously for 5 hours after full charged. |
18. Equip with special adjustable-pitch fixed bracket. It could adjust the pump on 45℃ angle or other angle for easy watching. |
19. The chip in syringe pump is be processed by ourselves on SMT machine production line instead of by manual work, as weld every point by hand. |
20. CPU control, stable function, high reliability. |