Products

Patient Monitor

 Instruction     

 

Sun-501K multi-parameter patient monitor is our best selling product. 

The display is 7 inch high

resolution color TFT. It is equipped with 4 parameters including ECG, NIBP, SpO2, RESP. 

These four parameters can be flexible. You can choose different combinations as you need. 

This monitor is built-in rechargeable lithium battery. The working capacity is 5 hours. IBP is optional.

 

 

Features                                                                            

 

4 Standard parameters: ECG, NIBP, SpO2, RESP.

 

7 inch high resolution color TFT LCD display.

 

Real time S-T segment analysis, pace-maker detection.

 

Indication of incorrect manipulation and malfunction analysis.

 

Patient info input management function

 

Multi-lead ECG wave forms display in phase.

 

Large volume of tabular and graphic trends information storage and easy to recall.

 

Capture dynamic wave forms.

 

Efficient resistance to interference of defibrillator and HF knife.

 

UP to 4 hours working capacity of built-in rechargeable lithium battery.

 

Unique accessory management cabinet.

 

Networking capacity.

 

Option: ETCO2, Built-in recorder,trolley , wall shelf, temperature 

 

Be applicable for adult, pediatric and neonatal.

 

Specification     

 

Operation interface with Chinese and English. Finish all operations by keys and knobs.(Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.) design with full built-in module, stable and reliable performance.

 

7'' color TFT LCD with high-resolution displays patient parameter and waveform, and 

alarm, bed NO, clock, state and other information provided by the monitor synchronously.

 

Monitoring contents, scan speed, volume and output contents can be set optionally.

 

Storage of 480-hour trend data, and review of 40-second holographic waveform

 

Storage and review of 72-hour ECG waveform.

 

Function of NIBP review, storage for up to 2400 NIBP data.

 

Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.

 

Calculation of drug concentration.

 

Network: connecting with central station, other Bed observation and software updating. Connection mode: wireless and wired.

 

Built-in rechargeable battery for uninterrupted monitoring.

 

Print ECG, SpO2, RESP, BP and temperature data with one-key.

 

Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).

 

Analysis function for heart rate variability(HRV) (optional)

                                                                                                   

 

ECG

Lead mode; I,II,III,AVR,AVL,AVF,V
Gain:X0.25,X0.5,X1,X2
Heart Rate:15-300BPM(Adult) 15-350BPM(Neonatal) 
Resolution:1 BPM
Accuracy:+-1%
ST measurement Range:-2.0-+2.0mV
Accuracy:+-10%
Pacemaker:Yes
Sweep Speed:12.5 mm/s,25mm/s,50mm/s
Bandwidth:Diagnostic:0.05--130Hz
               Monitor:   0.5--40Hz
               Surgery:    1-20Hz

HR and Alarm Range

 

Adult: 15-300 bpm 

Neo/Ped: 15-350 bpm

Accuracy: 1 bpm

CMRR

Monitor: >105 db

Operation: 105 db

Diagnosis: >85 db

HR and Alarm Range

 

Adult: 15-300 bpm 

Neo/Ped: 15-350 bpm

Accuracy: 1 bpm

CMRR

Monitor: >105 db

Operation: 105 db

Diagnosis: >85 db

SPO2

Measure Range:0-100%
Resolution:1%
Accuracy:2%(70-100%)
Pulse Rate:20-250BPM
Resolution:1BPM
Accuracy:+-3BPM

RESP

Measure Range:0-150BrPM
Resolution:1BrPM
Accuracy:+-2%

Temp

Measure Range:0-50C
Resolution:0.1C
Accuracy:+-0.1C


NIBP

Work mode:Manual,Automatic,Continuous
Unit:mmHg,Kpa
Measure Range:
Adult: SYS:  40-270mmHg
          DIA:  10-210mmHg
         MEAN:20-230mmHg

Pediatric  SYS:40-200mmHg
             DIA: 10-150mmHg
            MEAN:20-165mmHg

Neonatal SYS:40-135mmHg
            DIA:10-100mmHg
           MEAN:20-110mmHg
Resolution:1mmHg
Accuracy:+-5mmHg

Pulse rate 

Measure range: 20-300 BPM
Accuracy: ±2 BPM
Resolution: 1 BPM

 

 

 

 

 

Press sensor

 

Sensitivity: 5 uV/V/mmHg
Accuracy (no sensor); ±2%or1mmHg
Band width:   Normal mode: DC~40Hz
Smooth mode: DC~12.5Hz

ETCO2

Measure range: 0% - 13%
Resolution: 1 mmHg
Accuracy : ±2 mmHg @ < 5.0% CO2 (at ATPS)
Respiration: 3 – 150 bpm
Depth of anesthesia (optional)
EEG sensitivity     ±400μV  
Noise    <2μVp-p , <0.4μV RMS,1-250Hz
CMRR    >100Db
Input impedance    >50Mohm
Sample rate      2000 samples/sec.(14 bits equivalent)
CSI and update   0-100.Filter 6-42Hz,1 sec.update
EMG            0-100logarithmic.Filter75-85Hz,1sec.update 
BS%            0-100%.filter 2-42 Hz,1 sec.update

 

 

 

 

 

HTB1_9_iIXXXXXa0XXXXq6xXFXXXs

 

 

                         SUN-501K

 

 

QQ20160120145511_.jpg

 

Back Up